REGEN.TYPE

Description

You can specify a user-defined external regen resistor or select the internal regen resistor. The values for REGEN.TYPE are shown below:

Type

Option

Description

–1

External Regen

External user-defined regen resistor

0

Internal Regen (if available)

Internal regen resistor

If a user-defined regen resistor is specified, then you must also define this resistor's resistance (REGEN.REXT ), heatup time (REGEN.TEXT ), and power (REGEN.WATTEXT ).

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

Type

Read/Write

Units

N/A

Range

–1 to 0

Default Value

0

Data Type

Integer

See Also

N/A

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported.

Fieldbus Information

EtherCATClosed ***EtherCAT is an open, high-performance Ethernet-based fieldbus system. The development goal of EtherCAT was to apply Ethernet to automation applications which require short data update times (also called cycle times) with low communication jitter (for synchronization purposes) and low hardware costs CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDOClosed PDO is a type of protocol frame used in some fieldbuses. A PDO contains one or more object dictionary entries, which define the application data transferred between devices. Mappable

REGEN.TYPE

3007h

03h

Signed8

-

-

Read/Write

No

EtherNet/IP

Name

ID

Hex

Data Type

Access

Units

REGEN.TYPE

2403

963

Signed8

Read/Write

-

PROFINET

Parameter

PNU

Data Type

Access

Units

REGEN.TYPE

2403

Signed8

Read/Write

-